CMR 183 Safe operation of air compressors

Department
Not stated
Year
1966
Collection
Regulation-wise digest (to 2017)
Under
CMR 183
In the DGMS Circulars (up to June 2017) compilation, pp. 446–447.
Open PDF at page 446

CMR 183 Safe operation of air compressors—In an incident in a mica mine a number of workers including three drillers were overcome by noxious gases delivered from a compressed air pipe line during drilling operation. Two of the drillers died within a short time.

An enquiry revealed that the electrically operated air compressor had been running for some time past with worn piston rings. The scraper rings were prominently worn out and some of them were broken and had got stuck inside the slot for rings on the piston. Understandably therefore, there had been abnormal loss of crankcase oil, before the incident. This oil which was being pumped to the air receiver and the pipe range along with the compressed air had settled down inside the receiver and along the length of the pipe range. Before the incident the compressor had been going out of order frequently due to carbon deposit on the valve seats etc, and the operator used to open the parts out, clean them in kerosene oil, and refill them. In this way the compressor was made to work again without attending to the main defect. After one of these cleaning operations, compressor was started but the pump delivering water for cooling the air at the intercooler failed. This allowed the compressed air temperature to rise igniting the kerosene oil on the air valves, which in turn initiated burning of the deposited lubricating oil in air receiver and in pipe range.

Noxious gases produced for the combustion of oil were delivered underground along with the compressed air to the drills which were being operated at the time by the deceased. It was apparent that the incident could have been avoided if only compressor was maintained properly as required under Reg. 173(1) of the MMR 1961. It would be realized that the incident might as well have resulted in a disaster involving large number of persons if there was an explosion inside the compressed air system.

To avoid similar accidents, the following precautionary measures should be taken in addition to the requirements of the regulations:

(a) Drain cocks should be provided not only below air-receiver but also at all low points along the pipe range.

(b) The drain cocks should be kept open during starting of the compressor and they should be closed after compressor has been started and clean air has been found coming out through the drain.

(c) A log book should be maintained to record consumption of oil per day, hourly reading of air pressure, temperature, cooling water flow, and other relevant particulars.

(d)When any serious defects such as excessive oil consumption, low pressure, high temperature etc. are noticed, the compressor should be stopped till the defects are rectified and the compressor is overhauled when required.

(e) Internal parts of compressor and pipeline should be washed with hot water and soda after they are cleaned with inflammable oil and before they are refitted.

It is further recommended that the compressor should be provided with the following control fittings, as far as possible:

1. a thermometer or a temperature recording device at the intercooler.

2. a thermostatic control which would cut off power in case of abnormal rise of air temperature.

(Cir. 10/1966)