Cir. 15/1965
Deletion of circulars on winding and haulage equipment
- Department
- Not stated
- Year
- 1965
- Collection
- Regulation-wise digest (to 2017)
- Under
- CMR 87/MMR 95
Deletion of circulars on winding and haulage equipment—In a recent review of the circulars relating to winding and haulage equipment issued in the past it Was observed that some of the circulars have either outlived their usefulness or they require updating/revision. Accordingly an exercise was undertaken to identify the deletion/amendment/revision which is necessary to remove any element of confusion or conflict. The results of this exercise are detailed below.
You are requested to carefully note the same.
TRANSPORT OF MEN AND MATERIAL—HAULAGE CMR 87/MMR 95
1. Installation of power cables belowground—Installation of power cables along haulage roadways should be generally avoided. The cables should be installed along travelling or other road-ways where roof and sides are adequately supported, and there is good ventilation.
Wherever cables are installed, they should be so placed and secured as to ensure maximum protection against mechanical damage of all kinds, and particularly that due to their own weight, bending or twisting, traffic and ground movements. Damage to cables or crushing at points of their support should also be avoided. Supports for cables should be spaced sufficiently close to prevent dangerous sagging.
(Cir. 15/1965)