CMR 116 Fire risk from compressed air—In order to minimise the risk of fire associated with the use of compressed air, the following precautions are suggested:
1. Leakage in pipe joints particularly the type that produces 'Squeal' leads to fire. As far as practicable plane- flanged joints should not be used in the pipe range. Only non-inflammable packing materials should be used at the joints.
2. Sealing of holes in pipes by packing should not be done. Only clamps of robust construction in conjunction with non-inflammable material should be used.
3. A compressed air pipe range should not be kept hurried.
4. A punctured hose should not be used.
(Cir. 17/1960)