Cir. 19/1969
Compulsory use of methane for demonstration of gas caps
- Department
- Not stated
- Year
- 1969
- Collection
- Regulation-wise digest (to 2017)
- Under
- CMR 157/MMR 151
7. Compulsory use of methane for demonstration of gas caps—As coal mines are now being treated as gassy, not only examinations for gas testing have to be conducted by the Directorate but the; mine management has also to arrange gas testing demonstration to teach and train workers and staff in gas testing. Vocational Training Centre have also been opened in different mines which have to provide gas testing facilities.
For demonstration of gas caps not only a suitable apparatus is needed but also suitable gas.
Different mixtures of gases like domestic cooking gas, vapour of volatile inflammable liquid are being used as substitute to methane. The texture of the cap and luminosity vary according to the hydrocarbon predominating in the mixture and usually fuel cap is more pronounced. The use of substitutes increases the probability of errors considerably that the trouble taken to obtain or produce methane is well justified by the results obtained. Therefore no gas other than methane should be used for demonstration purpose. Till methane is commercially available in cylinders. The mine managements could also easily produce methane from cow dung. Two old oil drums and a small length of pipe and a few valves is all that is required. Total cost of a small gas generating plant would not amount to more than Rs. 100/- Different kinds of apparatus are in use in mines. Gas testing demonstration apparatus should be such that the products of combustion of the lamp are kept separate from firedamp/air mixture. The flame of the lamp is easily adjusted while the lamp is in the apparatus. A definite percentage of methane is admitted in the gas chamber by use of varying lengths of capillary tubes so that error of reading of the instrument is avoided and candidates can see different types of caps at the same time. In addition to the gas cap demonstration chamber discussed above, every mine can improvise a flame safety lamp by adjusting its air inlets so that methane could be directly fed into the lamp by a flexible pipe. The gas could be varied by adjusting a valve. The candidates could handle this lamp which will not only show them gas cap but also give confidence for preparing the lamp for a test and properly testing for gas thereafter.
The above note is not meant to restrict on ingenuity in designing suitable apparatus. It gives only guidance to make necessary arrangements for demonstration for gas testing purposes. In case any clarification is needed concerned Joint Director may be consulted.
I (Cir. 19/1969)