3. Shot-firing in Second and Third degree gassy seams—Shotfirers do not always check for gas before firing each shot with the result that there is a possibility of the subsequent shots being fired in gas liberated by the previous shot. It is desirable that the shots are fired simultaneously, but this may not be always practicable specially in view of the present difficulty in importing multi shot exploders. Special attention should be paid to the practice of shotfiring to ensure that where shots are fired singly, the shotfirers check for gas before each shot is fired. The number of shots being fired by each shotfirer may also be reviewed. The number of shots may be reduced if it is found by actual observations that the shotfirer cannot fire all the shots already fixed with precautions laid down for shotfiring in Second and Third Degree gassy seams.