Cir. 30/1971
Support of partially stowed areas
- Department
- Not stated
- Year
- 1971
- Collection
- Regulation-wise digest (to 2017)
- Under
- CMR 102 / MMR 107
3. Support of partially stowed areas—A few fatal accidents from falls of roof occur every year to persons entering partially stowed galleries either for removing stowing pipes or for erecting or repairing stowing barricades. Investigations into such accidents have revealed that no arrangements were made at the site of accidents to support the roof. Perhaps, it is a general practice to withdraw supports from the places where sand is to be filled. But even in these areas wherever persons have to work, pass or remain for any length of time, adequate supports for their safety need to be left or erected till the voids are fully stowed.
(Cir. 30/1971)