Cir. 4/1965, Tech. 5/1975 & Tech. 3/1987
a defective exploder was issued to shot-firer for use leading to a fatal accident to the shot-firer
- Department
- Technical
- Year
- 1987
- Collection
- Regulation-wise digest (to 2017)
- Under
- CMR169/MMR163
a defective exploder was issued to shot-firer for use leading to a fatal accident to the shot-firer. On examination at the CMRS glaring defects were observed in the exploder involved. An extract from the CMRS report is reproduced below— "In the physical examination it was found that the connection to the neon lamp was disconnected and hence there is no visible light indication when the key of the exploder is kept in charged position. The connection of the switch has been found to be tampered. When the key of the exploder is turned, there is no visible light indication and output is continuously available at the firing terminals till the key is turned to the 'fire position'. This is undesirable.
Because of the tampering there is no time limit to the firing current impulse. This will affect the safety of the exploder." You are no doubt aware that an exploder in poor condition may fail to fire required number of shots thereby giving rise to misfires. It can also lead to dangerous consequences in gassy coalmines because safety during electric shot-firing in gassy atmosphere also depends upon safety features of exploder. These features could get disturbed due to poor maintenance. It is therefore emphasized that regular maintenance of exploders must be carried out as per the requirement of the regulations. Cleaning, overhauling and testing of exploders should be done strictly in accordance with the instructions given in maintenance manual issued by the manufacturers and it is advisable that the competent person responsible for cleaning and overhauling the exploders is thoroughly trained by the manufacturers of exploders.
3.0 It has been also brought to my notice that at times exploders are being repaired by unauthorised agencies. It is to be emphasized that only the work of maintenance of exploders is to be done at mine level and any servicing and repair of an approved exploder must be carried out only by the manufacturer of the exploder or by the agency authorised by the manufacturer and approved by DGMS. In this context, the agencies where repair work of various types of exploders can be carried out are indicated below :
Type of exploder l.
Agency for repair work Schaffler—350 IDL Chemicals Ltd.
Post Box No. 1 Sanat Nagar (IE)
P.O. Hyderabad-500 018 'Rihno' brand exploders M/s Electronic Equipment Manufacturing Co. 1, Acharya Jagdish Chandra Bose Road, Calcutta.
ME-6 (Six shot exploder)
(i) lELLtd.
34, Chowringhee, Calcutta-700 016
(ii) M/s Jivon & Co. (P) Ltd. 97, Gray street, Calcutta-5.
(iii) M/s Andrew Yule & Co. Ltd. Calcutta.
(iv) M/s Mining Craft, P.O. Raniganj.
ME—12 (Twelve shot exploders)
IEL Ltd. 74, Chowringhee, Calcutta-700 016 25 Shot Sanjoy exploder M/s Sanjoy Industries, Main Road, Jealgora, Dhanbad.
'Star' brand exploders M/s Electrical Equipment Corporation 13/63 Punjabi Bagh, New Delhi.
7. 25 Shot exploder of M/s Swastik M/s Swastik Mining Industries, Lal Bazar, P.O. Jharia, Dhanbad A repaired exploder shall not be brought into use unless accompanied by a Usability Certificate granted by the repairer clearly indicating that all the safety devices in the exploder are in order.
In addition, the Colliery Engineer must satisfy himself regarding the same and record in the book to be maintained for the purpose. The Usability Certificate should also indicate the nature of servicing and repair done and the results of tests done regarding (a) Duration of current impulse, (b) Output voltage, (c) Residual current.
4.0 Under Reg. 169(1) (c) (iii) of the CMR 1957, systematic records of every overhaul, test or repair of exploders are required to be maintained in a bound paged book. It is suggested that in this book, a few pages should be ear-marked for each exploder. A complete history of maintenance, test repair, overhaul etc. of every exploder in use, since the date of its introduction, should be kept recorded on these pages. Every entry in the book shall be countersigned by the engineer.
(Cir. 4/1965, Tech. 5/1975 & Tech. 3/1987)