Cir. 42/1961
Use of Flame Safety lamps
- Department
- Not stated
- Year
- 1961
- Collection
- Regulation-wise digest (to 2017)
- Under
- CMR 154
CMR 154
1. Use of Flame Safety lamps—Flame Safety lamps are required to be issued to all shotfirers and supervisory staff and should be kept burning at all places where electrical equipment is in use. In addition to above it is advisable to provide one flame safety lamp for every group of persons working in a face or elsewhere.
While for shotfirers and supervisory staff it is necessary to provide gas testing lamps with relighting device, in other cases ordinary flame safety lamp would be adequate. It is observed that adequate number of flame safety lamps are not provided to meet with the above requirements. The following types of flame safety lamps are available from indigenous sources:
Velox Type GL5--without relighting device.
Velox Type GL60 & GL7—with relighting device.
Necessary action to comply with the above requirements shall be taken.
2. Flood-lights in Depillaring areas—Suitable Hood lighting should be provided in every depillaring area. In mines other than those to which regulations 122(2) do not apply and are not in Second and Third degree, this may be done by providing every such area with four or more 250 watt bulbs (or equivalent lighting) so placed that glare and deep shadows are avoided.
In mines to which regulations 122(2) apply and are in Second and Third degree, every depillaring area shall be provided with general lighting by a cluster of not less than 15-20 cap safety lamps placed on a suitable stand in the area. These lamps should be in addition to the lamps carried by individual workman.
(Cir. 42/1961)