Skip to content

Cir. 43/1970

Emergency Stop Valve on steam/compressed air operated winding engines

Department
Not stated
Year
1970
Collection
Regulation-wise digest (to 2017)
Under
CMR 73 / MMR 80
In the DGMS Circulars (up to June 2017) compilation, p. 100.
Open PDF at page 100

5. Emergency Stop Valve on steam/compressed air operated winding engines— Investigation into a few cases of overwind in steam operated winding engines has revealed that while hoisting was in progress the engine driver tried control the supply of steam to the engine but could not do so because the steam regulating valve accidentally became inoperative. The valve was either stuck up or one of its components failed. In the situation the supply of steam to the engine was not instantly stopped and the motion of the cages could not be controlled by the brakes. The driver lost presence of mind and failed to put the engine valve lever to neutral position and by the time steam was stopped by the screw type stop valve an overwind of cage occurred.

Since it is likely that the operation of steam regulating valve may get obstructed while the engines are working, the engine driver under unexpected situation may loose the presence of mind and that the supply of steam to the engine cannot be instantly stopped by the conventional screw type valve generally provided on the steam range, it is considered safe to provide a suitable non-screw type spring loaded stop valve, either electric solenoids operated or mechanically operated by levers, immediately before the engine regulating valve so that during any emergency the engine driver can easily and effectively cut off the supply of steam to the engine from his operating position. Installation of above said emergency stop valve will be useful with automatic contrivances as well.

Therefore, one emergency stop valve as described above before the engine regulating valve on each steam winding engine installation shall be provided.

This also applies to compressed air operated engines.

(Cir. 43/1970)