Open PDF at page 352

3. Precautions against roof layering of gas—Attention is drawn to the phenomenon of 'roof layering' in the workings and the dangers arising therefrom. In a recent case, it was revealed that nearly 38% gas had accumulated at the roof level at a working face but its concentration was only 1% one foot below the roof. A layer of gas is also known to travel along the roof against an air current for appreciable distance away from its source.

It is, therefore, necessary that test for gas should be made as near the roof as possible, and, for this purpose, flame safety lamps fitted with lop air feed arrangement should be used while testing for gas. In addition, air samples should be frequently collected at the roof level of the working faces and analysed for the presence of CH4. Whenever a concentration of gas is found near the roof, necessary steps should be taken to remove it and no blasting should be done at the face, till the gas had been cleared.

(Cir. 48/1959)