Skip to content

Cir. 54/1971

Machinery operators to hold gas testing certificates

Department
Not stated
Year
1971
Collection
Regulation-wise digest (to 2017)
Under
CMR 186
In the DGMS Circulars (up to June 2017) compilation, pp. 447–448.
Open PDF at page 447

CMR 186

1. Machinery operators to hold gas testing certificates—The provisions of Reg. 186(2) of the CMR 1957 require that in gassy seams of Second and Third degree, no person shall be appointed to supervise or operate any electrical machinery, apparatus or appliance other than a telephone or signaling device of an electric lamp or light, unless he holds a Gas Testing Certificate.

2. The above provision came into force in the year 1957 and during the last fourteen years many machinery operators have obtained Gas Testing Certificate. A number of them, however, have still to acquire the certificate, which is a matter of concern when viewed in the background of the importance of the measure and the time allowed to acquire the skill and quality at the examination.

3. Because of the importance of the issue it came up for discussion at the recent meetings of the Standing Safety Advisory Committee when the members expressed the view that not only machinery operators but every person employed in a belowground mine should be trained so as to be competent to check for presence of inflammable gas. This being the ultimate goal, it is requested to expedite the training of machinery operators in the first instance and also assist them in appearing at the examinations.

4. Now that Vocational Training Centres have been established in various parts of coalfields covering practically all mines and under Rule 17 of the Mines Vocational Rules, 1966, every person eligible to appear at the Gas Testing Examination has to undergo a course of training as detailed in the VIII schedule, the infrastructure for complying with the statute appears to have been well taken care of. A little concerted effort to draw these persons to the training centres by offering some incentive and to ensure that-they acquire the required skill would further the interests of safety in mines.

5. Members of the Standing Safety Advisory Committee also made another valid suggestion that no person should be appointed as machinery operator unless he possesses Gas Testing Certificate.

6. It is needless to emphasize that heavy responsibility rests on machinery operator specially if inflammable gas were to appear at the site of an energized electrical apparatus. Rule 126 of the Indian Electricity Rules, 1956 requires that in a situation like this, supply of electricity to the apparatus shall be immediately disconnected and incident reported to an official of the mine. If an operator is not able to detect presence of inflammable gas on a flame safety lamp it is obvious that he will not be in a position to comply with the rule and take necessary precaution.

Managements working seams of Second and Third Degree of gassiness should treat the issue with the seriousness it deserves.

(Cir. 54/1971)