Skip to content

Cir. 56/1964

Occurrence of fire in quarry debris

Department
Not stated
Year
1964
Collection
Regulation-wise digest (to 2017)
Under
CMR 117
In the DGMS Circulars (up to June 2017) compilation, p. 298.
Open PDF at page 298

2. Occurrence of fire in quarry debris—There have been a number of cases of fire occurring in quarry debris either due to spontaneous heating or due to preparation of soft coke or deposition of heated material or hot ashes etc. over the quarry debris. There have also been instances of such fires travelling underground through the entrances to underground workings from the quarry. Needless to say once the fire goes underground it becomes very difficult to control it; there is usually huge loss of coal and considerable expense is involved in dealing with the fire.

To reduce the chances of occurrence of fires in quarries, Reg. 117 of CMR 1957 lays down certain precautions to be taken, but these precautions are apparently not enough for preventing a fire, should it occur in a quarry, from going into the underground workings started from the quarry. It is therefore recommended that in addition to the usual precautions, a zone of at least 15 metres from the entrances to underground workings and the coal face in the quarry should be kept clean of all quarry debris, wild or herbaceous plants and any other carbonaceous material. This zone should be maintained scrupulously clean right up to the bed of the quarry.

(Cir. 56/1964)

Reproduced from the official DGMS circular compilations for public reference. The PDF is the authoritative text; DGMS may have amended or withdrawn older instructions since.