Skip to content

Cir. 7/1964

Danger of layering of inflammable gas near the roof

Department
Not stated
Year
1964
Collection
Regulation-wise digest (to 2017)
Under
CMR 146
In the DGMS Circulars (up to June 2017) compilation, p. 353.
Open PDF at page 353

5. Danger of layering of inflammable gas near the roof—During a recent inspection of a gassy mine, the following accumulations of inflammable gas were obtained in the roadways: — at roof level 3" below roof 6" below roof 9" below roof

1. A dip face 10% 1%

2. Another dip face 10% 1 ½%

3. A third dip face 10% 8% 0.5%

4. A level gallery 3-10% ½%

5. Another level gallery 10% 8% 3% 2 ½% The readings above are typical of conditions occurring in a gassy mine where the ventilation current is not turbulent.

In its report on Mine Ventilation Standards, the Technical Committee on Mining Safety Standards has also observed that "velocity of air current is a very important factor in the removal of methane layering".

The need for having a turbulent flow of air in working areas should always be kept in mind while planning and executing measures to deal with the danger of inflammable gas in mines.

(Cir. 7/1964)

Reproduced from the official DGMS circular compilations for public reference. The PDF is the authoritative text; DGMS may have amended or withdrawn older instructions since.