5. Footpaths in opencast mines—There have been instances when persons walking/travelling in open-cast workings have met with accidents due to slipping, failure of safety rope etc. While analysing such accidents, it is revealed that, by and large, suitable roads or foot paths for travelling are not provided in the open-cast workings. Reg. 88 of CMR '57 and Reg. 96 of MMR '61 prescribe the type of travelling road to be provided for persons to travel to and from there working places in an underground mine. Reg. 115(5) of CMR 57 and Reg. 118(5) of MMR '61 prescribe dimensions of roads or foot paths along which loads are carried by human agency. Necessary action to suitably amend the regulation in the matter is being taken. In the mean-time managements are advised to provide and maintain foot paths (travelling roads) in. opencast workings for safe travel of working persons to and from their working places (benches) according to the specifications given below—

(a) Breadth shall not be less than 1m;

(b) At every place where the inclination exceeds 15° from the horizontal, level steps shall be provided such that the vertical height of every step does not exceed 0.18 m and the distance from the edge to the back is not less than 0.35 m or where inclination exceeds 30°, suitable ladders may be provided;

(c) Where inclination exceeds 45 degrees from the horizontal, be provided, in addition to steps or ladders, with hand rails or ropes to ensure safe travel; and

(d) Where the inclination exceeds 60 degrees from the horizontal, be provided, in addition to the steps or ladders and hand rails or ropes, with suitable platforms at intervals not exceeding 10 metres measured along the slope.