Skip to content

Cir. Tech. Sapicom 1/1990

Accidents/incidents due to overwinding of conveyance in shafts

Department
Technical
Year
1990
Collection
Regulation-wise digest (to 2017)
Under
CMR 74/MMR 82
In the DGMS Circulars (up to June 2017) compilation, pp. 105–108.
Open PDF at page 105

7. Accidents/incidents due to overwinding of conveyance in shafts— 1.0 An in-depth analysis of accidents/incidents due to winding system in mines during the years 1984 to 1988 has revealed that:

(i) Out of 90 accidents/incidents connected with winding operations, 25 i.e. 27.8% were due to overwinding (Appendices 'A' & 'B;); and

(ii) Out of the 25 cases of overwinding

(a) 17 occurred in coal mines and 8 in metalliferous mines;

(b) 24, i.e. 96% were due to improper maintenance of brake and failure of automatic contrivance (Appendix 'C');

(c) 9 occurred in shafts having depth not exceeding 100 metres, 8 in shafts having depths between 101 and 200 metres and remaining 8 in shafts exceeding 200 metres in-depth (Appendix 'D');

(iii) A number of defective practices were responsible for the above cases of overwinding. The most repeated amongst these were;

(a) Attempting to control the speed of steam winder by reversing the steam supply to the engines in absence of proper braking system, particularly when the conveyance was near the landing;

(b) Deliberately keeping the emergency brakes defunct by spragging the re-set lever of the automatic contrivance.

2.0 With a view to minimise accidents/incidents connected with winding operations :

2.1 Managements are requested to ensure that the winding installations fully comply with the provisions of Regulations 74(2), 74(4), 75(3), 76(6) and 76(7) of the Coal Mines Regulations, 1957 and in case of Metalliferous Mines with the provisions contained in Regulations 82(2), 82(4) 83(3), 84(6) and 84(7) of the Metalliferous Mines Regulations, 1961; and 2.2 It is recommended that :

2.2.1 automatic contrivance, including power brake, be provided with all winding engines used for man-winding;

2.2.2 suitable pit-bottom buffers be provided in all shafts used for man-winding in order to prevent injury to persons due to hard landing of cage-conveyance;

3.0 It is further recommended that each mining company should :

3.1 acquire and use testing facility for destructive and non- destructive testing of winding rope and suspension gear.

3.2 establish a well-equipped quality control cell which should not only ensure purchase/procurement of good quality equipment/apparatus, but should also monitor the performance of the same during use.

3.3 set-up a task force to survey all winders and winding installations and to frame and thereafter monitor implementation of a time bound programme for their renovation/replacement as deemed necessary; and 3.4 arrange for proper training for systematic testing and maintenance of the winding installations to be imparted to all those who are responsible for the up-keep of winding equipment, such as, engineers and supervisory competent personnel.

APPENDIX 'A' ACCIDENTS/INCIDENTS DUE TO WINDING Fatal Serious Incidents Total Year Coal Metal Coal Metal Coal Metal Coal Metal - - - - TOTAL APPENDIX 'B' OVERWINDING IN MINES Year Coal Metal Total TOTAL APPENDIX -C' ANALYSIS OF OVERWINDING (CAUSE-WISE)

Cause Coal Metal Total BRAKE NOT MAINTAINED FAILURE OF AUTOMATIC SUDDEN WINDER REVERSAL OF — TOTAL APPENDIX 'D' ANALYSIS OF OVERWINDING (ALL MINES-DEPTHWISE)

DEPTH OF SHAFT (M)

NO. OF OVERWINDS 0-100 101-200 201-300 301-400 401-500 Exceeding 500 TOTAL 2 25 (Cir. Tech. Sapicom 1/1990)