Circular No. 9 of 2008

Use of Local Methane Detector (LMD) in underground Coal Mines

Department
Not stated
Dated
12/03/2009
Collection
Circulars 1995–2017
Topic
Circulars and notifications, 1995–June 2017
In the DGMS Circulars (up to June 2017) compilation, pp. 1003–1005.
Open PDF at page 1003

Circular No. 9 of 2008 issued on 02.12.2008 and Circular No. 1 of 2009 issued on 16.01.2009) may kindly be replaced with these issued on 18th February 2009.

Inconvenience caused is deeply regretted.

No. DGMS (Tech)/Circular No./ 06 of 2009 Dhanbad, Dated – 12/03/2009 To, Owner/Agent/Manager of all coal Mines.

Sub:- Use of Local Methane Detector (LMD) in underground Coal Mines.

Firedamp or Methane is the most important of the mine gases and has caused more loss of life in mines than any other gas. Methane or firedamp are synonymous to each other. Firedamp is a mixture of inflammable gases emitted from strata and besides methane, which is the principal constituent of mixture, contains higher hydrocarbons, carbon dioxide, nitrogen and water vapour. Methane mixed with air in certain proportions forms explosive mixtures. The approximate lower and upper limits of flammability of methane air mixtures are 5 and 14.8% of CH4. Firedamp explosions have been responsible for deaths of many miners throughout the history of mining. Statistical figure indicated that during the period 1901 to 2007 there had been 37 cases of explosion (major accidents/disaster) resulting in death of 1258 persons.

Lots of emphasis were given since then in detection and measurement of CH4 concentration in mine atmosphere. Methane emission at a face is affected by factors such as type of work going on at the face and machinery used, the time of observation in relation to the cycle of work at face, the rate of coal output and face advance, barometric pressure change, variation in air velocity., method of mining and roof control and geological factors. Sudden emission of methane may occur as instantaneous coal and gas outburst, sudden emission from roof or floor strata, as gas blower from the coal seam or adjacent strata. Thus, every mine having potential hazard on methane emission should have methane monitoring system installed and maintained.

In this connection Regulation 145(1)(e) of Coal Mines Regulation 1957 says that – (i)

If the determination of inflammable gas in any ventilating district shows the percentage of inflammable gas to exceed 1.25 percent, the supply of electric energy shall be cut-off immediately from all cables and apparatus working in the district.

(ii)

Again, Rule 126(4)(d) of Indian Electricity Rules, 1956 says that in any coal seam of second or third degree gassiness or in the danger zone of oil mines :- The supplied energy shall be disconnected from all apparatus (including portable & transportable apparatus) working in the vicinity of a place where inflammable gas has been detected by the lowered flame of a flame safety lamp kept and maintained in a continuous state of illumination. The apparatus shall be interlocked with controlling switch in such a manner as to disconnect power supply automatically in the event inflammable gas exceeds 1.25% at the place. Further, if an approved apparatus for automatic detection of % of inflammable gas or vapour in addition to Flame Safety Lamp is provided in any working district or place such apparatus shall be interlocked with portable or transportable equipment.

Thus looking into the all above aspects and considering high production and mechanization, it is suggested to install a LMD (Local Methane Detector) which can automatically and continuously detect % inflammable gas at all mines having II/III degree gassy seams at following places :- (i)

District/Faces having continuous mining machine.

(ii)

Return side of district/Longwall faces (iii)

Return airway having Electrical motors.

(iv)

Main return airway.

Though the power supply in a district has to be discontinued whenever the % of inflammable gas reaches 1.25, the power to the ventilating fans (auxiliary/booster) shall be so arranged that they run continuously.

It is expected that al owner, agent and manger shall implement this circular with right spirit.