gyq@5R/Government of India Ministry of Labour & Employment /EHQ, Dhanbad, dated No.

From:

n —C; 9—: 2016 Director General of Mines Safety Directorate General of Mines Safety P.O & Distt: Dhanabd - 826001.

To Shri N. Ajayan — Vice President M/s. Kirloskar Electric Co. Ltd.

Post Box no. 112, Unit-II Gokul Road Hubli-580 030(Karnataka).

Sub:

Ref:

Renewal of DGMS approval No. 226 Group-I of 1982 under Regulation 181 (3) of the Coal Mines Regulations, 1957 for flameproof fan cooled foot mounted squirrel cage induction motor rated at 37 KW, 415 V, 75 A, 4 pole, 1475 RPM, 3 phase, 50 Hz in frame size-LE225M conforming to IS/IEC 60079-1:2007 and IS/IEC 60079-0:2004 manufactured by M/s. Kirloskar Electric Co. Ltd., Hubli for use in belowground Coal Mines.

CIMFR test report Nos. CIMFR/TC/SR/H480 dated 05.10.2012and CIMFR/TC/S/1018 dated 08.10.2014.

IDENTIFICATION MARK DGMS APPROVAL NO. 226 Group-I of 1982 Dear Sir, Please refer to your letter No. KEC/DGMS/LE225/CM dated 14.01.2016 and subsequent correspondence thereupon the above subject.

Based on DGMS approval No. 226 Group-I of 1982 issued by this Directorate's letter No. dated 21.10.1982, BIS Licence Nc. CM/l--4630962 and above test reports under reference, I hereby renew the approval upto 05.12.2020 from the date of expiry i.e. from 05.12.2015 for use belowground in Coal Mines, subject to compliance with conditions stipulated in the original approval as well as annexure enclosed with this renewal letter.

The application for renewal should be made at least three months before the date of expiry of the approval.

Encl : Annexure Yours faithfully, (Rahul Guha)

Director General of Mines Safety Annexure DGMS approval No, 226 Group-I of 1982 renewed by this Directorate's letter No.

........................./EHQ Conditions for renewal of DGMS approval No. 226 Group-I of 1982 under Regulation 181 (3)

of the Coal Mines Regulations, 1957 for flameproof fan cooled foot mounted squirrel cage induction motor rated at 37 KW, 415 V, 75 A, 4 pole, 1475 RPM, 3 phase, 50 Hz in frame size-LE225M conforming to IS/IEC 60079-1:2007 and IS/IEC 60079-0:2004 manufactured by M/s. Kirloskar Electric Co. Ltd., Hubli for use in belowground Coal Mines.

1.

2.

3.

4.

5.

6.

(i) Every unit shall carry conspicuously in a permanent manner the aforesaid identification mark, i.e. 'DGMS APPROVAL NO. 226 Group-I of 1982 renewed vide DGMS letter No. .

. ......./EHQ dated....

In addition, every unit shall also carry permanently this Directorate's approval mark as given below :

(ii) In the nameplate marking shall be in accordance with the applicable requirements of the relevant standards.

(a)The design of the electriCal circuit shall not be changed without obtaining prior approval from this Directorate.

(b)Conspicuous warning inscriptions against opening the cover of the main enclosure or of any apparatus which gives access to the flameproof enclosures on live parts or which is designed to receive cable attachment unless the supply to the unit is isolated at source, shall be affixed permanently on the respective part to ensure that all live parts within the unit are made dead and safe.

Spare parts shall be made readily available to the user as and when required for proper maintenance of the equipment.

(a) The customer shall be supplied the copy of this approval letter, the test report from the testing laboratory with the lab certified drawing , an extract of the condition & special conditions, maintenance schedule, if any, recommended by the testing laboratory in their test report(s) so as to maintain safety features of apparatus/equipment.

(b) The customer shall also be provided a copy of factory test report along with drawings, instruction manual on the installation, operation and maihtenance of the equipment and spares parts catalogue at the time of delivery of the equipment.

The user shall furnish the performance report of the equipment directly to this Directorate after one (01) year of actual use.

Any modification to the equipment that might be considered necessary at a later date shall be effected upon being so directed by this Directorate.

Contd.P-2 7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

-2- An officer of this Directorate may at any time draw a sampie either from the factory or from the user and get it tested at the cost of the manufacturer. If the test reports are not satisfactory, this approval shall be deemed to be suspended.

If there occurs any revision of standards applicable to the product/equipment, the manufacturer shali get the product/equipment tested as per revised standards and submit test reports to the customer for information and to this Directorate for further approval/renewal.

In case of aluminium die-cast rotor of the motor, the rotor shall not be dismantled, assembled or kept exposed in the explosive gassy atmospheres to prevent incendive sparking. A caution plate "Aluminium Die-Cast Rotor:. Not to be dismantled, assembled or kept exposed in explosive gas atmosphere" shall be provided at conspicuous place without affecting flameproof features of the motor, indicating that the motor is having aluminium die-cast rotor. Operation & maintenance manual of the motor shall also indicate the danger for aluminium die cast rotor due to incendive sparking.

The cable entry devices, threaded adaptors and stopping plugs shall be suitable for the equipment and be considered as a part of equipment (not a component). The cable entry device and cabling methods used shall be suitable for their intended duty and for the special type of cable used in mining. Such cable entry devices shall be duly certified as per relevant IS/IEC standards.

In case of any permissible variations issued from this Directorate, they shall also be read along with this letter and the original approval letter.

While seeking renewal of approval, valid BIS license in the case of Indian manufacturers and in case of foreign manufacturers, QAR/QAN as may be applicable shall be submitted.

The approval is renewed upto 95.12.2020 from the date Qf expiry i.e. from 05.12.2015.

The equipment manufactured subsequently shall be identical to the proto type tested at CIMFR vide test report Nos. CIMFR/TC/SR/H480 dated 05.10.2012and CIMFR/TC/S/1018 dated 08.10.2014.

At the time of applying for renewal, details of supply with name of mines, purchase order and date Shail be furnished with the application.

if at any time any of the conditions subject to which this approval has been granted, is violated or not complied with, this approval shall be deemed to have been revoked with immediate effect.

The above approval may be amended or withdrawn at any time, if considered so necessary in the interest of safety and is being issued without prejudice to any other provisions of law which may be or may become applicable at any time.

(Rahul Guha)

Director General of Mines Safety