Skip to content

DGMS Circular (Approval)No. 04 of 2013

Revised Standards for testing and use of Resin Capsules as grunting material for Roof bolting purposes in the…

Department
Approval
Dated
19.07.2013
Collection
Circulars 1995–2017
Topic
Circulars and notifications, 1995–June 2017
In the DGMS Circulars (up to June 2017) compilation, pp. 1160–1169.
Open PDF at page 1160

DGMS Circular (Approval)No.04 of 2013, Dhanbad, dated 19.07.2013 To, The Owner/Agent/Manager of all belowground coal mines.

Subject:- Revised Standards for testing and use of Resin Capsules as grunting material for Roof bolting purposes in the belowground workings of coal mines.

1.0 BACKGROND:

1.1 On 28th May,2013, a technical workshop was held at DGMS(HQ), Dhanbad for the purpose of reviewing the existing standards on use of resin capsules as grouting medium for supporting purposes in the belowground workings of mines, as notified vide DGMS/S&T/Tech.Cir.(Approval) No .03 dated 22/09/2010. The workshop was attend with representation from many manufactures, users, Scientific institutions like ISM-Dhanbad, CMPDIL-Ranchi, B.I.S, etc.

1.2 After deliberating in depth and carefully considering views of all stake holders and other expert opinions based on the experience and technical inputs, the following revised standards for using resin capsules as grouting medium for supporting purposes in the belowground working of mines, was involved, 2.0 (A) General:

Parameter Standard Gel Time & Setting time:

 For FAST SET type  For Slow SET type  23 Seconds (Minimum) to 54 Seconds (Maximum)

 134 Seconds(minimum) to 202 Seconds (maximum Reaction temperature(.c)

Not more than 80.

Thermal Stability  At 5° C for one hour  At 45° C for one hour The sample Shall meet the get time and setting time stipulations as mentioned above.

(B) PHYSICO-MECHANICAL PROPERTIES:

Parameter Standard Compressive Strength(Applicable for slow-set type of resin only)

 30 minutes,  24 hours.

 30.0 MPa(min)

 80.0 Mpa(min)

Bond Strength Test:

 30 minutes.

 24 hours.

 10.0 Tonnes  15.0 Tonnes Shear Test:

The measured strength as per procedure defined in Annexure-1.

The sample shall record a minimum of 19 MPa Shrinkage testApplicable for slow-set type of resin only)

 24 hrs  7 days  0.01%(max)

 0.01%(max)

(C)OTHER PROPERTIES:

Parameter Standard Flammability Test The product should be of very low flammability.

3.0 Therefore , for any resin capsule manufactured by a firm to be used as grouting mediums in mine for supporting purposes, it shall be ensured that all stipulations vide para 2.0 of this circular are satisfactorily met with.

4.0 Additionally, the manufacturers, test houses and the users shall also ensure certain minimum requirements as enumerated below.

a) TEST HOUSES:

For assessing the above standard properties of resin capsules and for sake of ensuring uniformity amongst the test houses, tests as per the procedure shown in Annexure-1 shall be performed by the approved test houses.

b) MANUFACTURERS:

For ensuring that every batch resin capsules produced by a manufacturer complies with the standards laid above, the manufacturers shall ensure the requirements on minimum facilities in their respective manufacturing premises as stipulated in Annexure-2 to this Circular.

C) MINING COMPANIES:

For ensuring strict compliance with the stipulated standards of resin capsules Vide para 2.0 of this circular, use mining companies shall strict compliance with stipulations as per Annexure-3 to this circular.

5.0 As provided under Regulation 181(3) of the Coal Mines Regulations 1957 and the earlier published GSR 160 vide Gazette notification No.35 date New Delhi August 24th August 30th 2008 in part –II, Section 3, sub-section(i), the standards for using resin capsules as grouting medium for supporting purposes in the workings of belowground coal mines, as stipulated at para 2.0 along with Annexure 1,2 and 3 to this circular, is considered as approved by the Chief Inspector of Mines by this general order in writing, from the date of issue of this circular. It may be noted that no specific approval will be required from this Directorate in this regard.

6.0 All Owners/Agents/Managers of belowground Coal mines are therefore, advised to ensure strict compliance with this circular in respect of using resin capsules as grouting medium for supporting purposes in the belowground workings.

Sd/- (R.Guha)

Director General of Mines Safety Encl: Annexure 1,2 and 3.

ANNEXURE-1 IMPORTANT REQUIREMENTS OF THE TEST HOUSE ************************************** 1.0 GENERAL REQUIREMENTS:- 1.1 Every laboratory engaged in testing of samples of resin capsules shall develop suitable protocol in respect of the receipt of unhampered samples. The details of the protocol as above shall be notified to every manufacturing firm seeking test of resin capsules.

1.2 At least, 100 numbers of 24 mm dia X 600 mm or equivalent sized resin capsules shall be received from the manufactures for the purpose of testing.

2.0 STA NDARD PROCEDURES TO BE ADOPTED BY APPROVED TEST HOUSES FOR LABORATORY TESTING OF RESIN CAPSULES:

2.1 METHOD OF TEST FOR GEL TIME & SETTING TIME OF RESIN CAPSULE (a)

DEFINITION Period during which a Resin matrix and proportionate catalyst can mixed evenly befor it begins to turn from fluid to solid state. Set time is the taken from time from the get state to the hardened state.

(b)

PREPARATION OF TEST SPECIMEN Weight at least 25 grams of Resin matrix into a plastic mug and note the mass of resin matrix taken and cover the resin matrix with a small piece of film. Onto the film in the cup, weight out, to the accuracy of the quantity of the catalyst proportionately as available in the resin capsules, ensuring that the two substances do not mix any way. Condition the cup and contents in the conditioner until the temperature of the contents is stable at 27±2°C. Retaining the cup in the conditioner and using the Spatula, scrape the whole quantity of catalyst from the film into the resin matrix.

(c)

PROCEDURE Immediately start the stop watch begin mixing the resin matrix and catalyst together and continue mixing till the mixture turns from fluid to beginning of hardening state and finally hardens. Take a pin and try to insert at regular intervals of 2 seconds, when the pin starts hitting the surface, note the time. This is the total of gel and time.

(d)

INSTRUENTS REQUIRED FOR TESTING (a)

Stop Watch (b)

Plastic Cup (c)

Electronic Weighing Scale (d)

Plastic Film (e)

Metal Alpines 2.2.A METHOD OF TEST FOR MAXIMUM REACTION TEMPERATURE OF RESIN CAPSULE

(a) PREPARATION OF TEST SPECIMEN 100gram resin matrix and proportionate quantity of Catalyst in proportion as stipulated by the manufacturer are mixed thoroughly and put into a glass beaker of 5 cm diameter.

(b) PROCEDURE The main know of the mercury thermometer/thermo-couple is coated with any mould oil and is inserted into the resin mix up to maximum 25 mm and the maximum temperature shown in the thermometer is recorded for 3 tests and the mean the value shall be recorded as final result.

(c) INSTUMENTS REQUIRED FOR TESTING (A) Beaker of 5 cm dia : 200ml. capacity (B) Mercury thermometer/ : 150 degree C max.

Thermo-couple 2.2.B METHOD OF TEST FOR THERMAL STABILITY OF RESIN CAPSULE

(a) PREPARATION OF TEST SPECIMEN Keep 3 nos of resin capsules at 5 degree C for one hour. Remove the samples and condition till they achieve a temperature of 27=/-2 degree C. Keep the same samples 3 nos. of Resin Capsules at 45 degree C for another one hour and then again condition all the Resin Capsules till 27+/-2 degree C.

(b) PROCEDURE Measure the Gel time and set time of all the by the procedure as prescribed in 2.1 as above.

(c) OBSERVATION The Gel time and set time of all the specimens shall be within specified limit as prescribed in the standards.

(d) INSTRUMENTS REQUIRED FOR TESTING (A) Refrigerator-1 No (B) Oven- 1 No (C) Stop Watch (D) Plastic Cup (E) Electronic Weighing Scale (F) Plastic film (G) Metal Allpin 2.3.(1) METHOD OF TEST FOR COMPRESSIVE STRENGTH OF SLOW SET RESIN CAPSULE (a)

PREPARATION OF TEST SPECIMEN Prepare a test specimen from the same batch of Resin each measuring 50mmX 50mmX50mm.

Prepare the test specimens, including the conditioning, proportioning and mixing of Resin matrix & Catalyst and conditioning and filling of the moulds, but casting and curing the specimens at 27 degree+/-degree C.

(b)

Carry out all the tests at 27 degree +/-2 degree C after 30 minutes and 24 hours after preparation of the test specimens. The test duration shall be counted from the preparation of the test moulds.

Measure the width and thickness of each specimen at its centre to the nearest 0.1mm and calculate the cross-sectional area.

Wipe clean the bearing surface of the testing machine and any auxiliary platens. Remove any loose grit or other material from the surfaces of the cube that are to be in contact with the compression platens. Place the test cube in the machine in such a manner that the load is applied to sides of the test cubes as cast , i.e not to the top and the top and the bottom. Place the cube on the lower machine platen and carefully centre. Do not use any packing at any of the interfaces between the test specimen, auxiliary platens, spacing blocks and machine platens.

Apply load (without shock)and increase it continuously at 45(N/mm2)minute.

(C)

OBSERVATION The compressive strength of each cube is calculated to the nearest of 0.1 MPa by maximum load(N)/original cross sectional area (mm2).

30 minutes duration compressive strength of 8 specimens is taken and the minimum and maximum reading are discarded and the mean value of the middle 6 readings is to be taken as result. Similar procedure is applied for 24 hours duration compressive strength testing.

(d)

INSTRUMENTS REQUIRED FOR TESTING (a)

Compressive Strength Machine :50 Tonnes Capacity (b)

Cube Moulds (50mm):As per IS:10086:1982 (c)

Poking Rod: As per IS:10086:1982 (d)

Gauging Trowel: 100-150 mm lengthen & weighing 210+/-10 grams.

2.3(2) METHOD OF TESTING OF BOND STRENGTH OF RESIN CAPSULE (a)

PREPERATION A pipe of 25 mm inner diameter and 37.5 mm outer diameter, 300 mm with 27X3 internal metric threads, and a 22 mm diameter roof bolt bar of appropriate lengths to accommodate a normal hydraulic jack, with suitable threading on one end for a length of at least 150 mm are taken. The test specimen shall be prepared by placing resin matrix and catalyst mixture into the threaded tube, inserting the roof bolt bar and rotating the bar in accordance with the instructions of the manufacture. The specimen shall be cured for the required duration of the test.

(b)

PROCEDURE Assemble the grouted pipe section as shown in figure-A and attract the dial indicator to the rear end the grouted roof bolt bar to indicate movement at the end of the bar.

(C)

OBSERBATION Take the maximum bond load reading till displaresin up to 5 mm and the mean value is calculated from three tests.

(d)

APPARATUS (A) A section of pipe of 25 mm ID & 37.5 mm OD, of a total length of 600 mm of which, 300 mm length shall be with 27X3 internal metric threads.

(B) Roof bolt bar of appropriate length to accommodate a normal hydraulic jack, including 150 mm threading with nut.

(c) Anchor machine 25 MT capacities with full assembly (jack with central hole, pump, and pressure gauge and hose pipe).

(d) Dial indicator for measuring displaresin of 0.02 mm least count with suitable fixing attachments.

(e) Steel collar for supporting hydraulic jack and pipe section.

2.3(3) METHOD OF TEST FOR SHEAR STRENGTH OF SET RESIN CAPSULE (a)

PREPARATION OF TESTSPECIMEN Separately weight out approximately 10 grams of Resin matrix and the recommended quantity of catalyst there for, as stipulated by the manufacture. Cool in a refrigerator. Place a metal washer on the film. Mix together the cooled Resin matrix and catalyst and mould a test specimen I the washer, using a knife blade to ensure that no air bubbles are entrapped I the specimen. Prepare at least 6 specimens. Before testing, condition the specimens for 3 hours at 50 degree C.

(b)

PROCEDURE Allow the specimens to cool in air to a temperature of 27+/-2 degree C, then measure the thickness of a specimen (in the washer),to the nearest 0.01 mm at several points. Position the specimen symmetrically in the punching tool assembly and screw the die home against the test specimen in the bolster, using only sufficient force to ensure that there is no clearance between the test piece and the adjacent surfaces of the die and the bolster. Position the punching tool assembly on the loading device and, using the punch, so apply a steadily increasing force to the test specimen that the test specimen fractures within 15 seconds to 45 seconds. Repeat the test on the remaining 5 test on the remaining 5 test specimens.

(c)

INSTRUMENTS REQUIRED FOR TESTING (A) Refrigerator: 4.0 degree C+/-1.0 degree C (B) Metal Washers :3.00 mm+/-0.1 mm thickness, 25.00 mm+/- 0.2 mm OD,& 21.6 mm +/- 0.5 mm ID (C) A Punching Tool assembly : Punch dia 12.575 mm to 12.591 mm & Die of diameter 12.707mm to 12.723 (D) Compressive Strength Machine : 2000N+/- 20 N to the punch at uniform rate.

(E) Film (LDPE): Compatible with Resin matrix & Catalyst 2.3(4) METHOD OF TEST FOR SHRINKAGE TEST OF SLOW SET RESIN CAPSULE

(a) PREPARATION OF TEST SPECIMEN The moulds shall be thinly covered with mineral oil. After this operation, the stainless steel or non-corroding metal reference insets with knurl heads shall be set to obtain a effective gauze length of 250 mm, care being taken to keep them clean and free of oil.

Clean appliances shall be used for mixing of Resin matrix and Catalyst in a proportion as stipulated by the manufacturer, at 27+/-2 degree C.

Immediately following the completion of mixing, the test specimen shall be mounded in the two layers, each layer being completed with jerks and vibration through Flow Table. After the top layer has been compacted, the Resin mix shall be labeled of flush with the top of the mould and the surface smoothen with a few strokes of the trowel. During the operation of mixing and moulding rubber hand gloves shall be used.

(b) PROCEDURE After filling the moulds, place them immediately in Humidifier at 27+/-2 degree C and 50+/-5% relative humidity for 24+/-2 Hours. Then remove the specimen from the moulds.

Measure the length at 27+/-2 degree C using the length comparator. Place the moulds back into the Humidifier at 27+/-2 degree C and 50+/-5% relative humidity.

Remove the specimens from the Humidifier and measure the length at 27+/-2 degree C using the length comparator.

After the specimens are measured at the age of 24 hours and 7 days, calculate the average difference in length of 3 specimens to the nearest 0.01% of the effective gauze length and report this difference as shrinkage.

(C) INSTRUMENTS REQUIRED FOR TESTING (A) Beam Mould : 25x25x282 mm Internal length IS:10086:1982 (B) Control Cabinet :90% Humidity max 50 degree C max.

(C) Length Comparator: As per IS:945:1980 (D) Gauzing Trowel: 100 to 150 mm length and mass 210+/-10 gram.

(E) Flow Table : IS:5512:1969 2.4 METHOD OF TEST FOR FLAMMABILITY OF CASTED RESIN CAPSULE

(a) OUTLINE OF THE METHOD The casted sheet of Resin Capsule is Subjected to a flame for specified time from Bunsen Burner and its Flammability evaluated.

(b) PREPARATION OF SPECIMEN Resin matrix and Catalyst are mixed thoroughly and a casted sheet is prepared. From this caste sheet four specimens shall be cut not less than 150mm long, 12.0+/-0.5mm wide, and 3.0+/- 0.15mm thick and a line shall be drawn, across the specimen at 75mm from the end to the longitudinal axis.

(c) PROCEDURE Test the specimen in draught-free atmosphere (See Figure-‘B’). Clamps the specimen in a rigid support at one and so that its longitudinal axis is horizontal and its transverse axis is at 45 deg.

To the horizontal, and line on the specimen at 75mm is clearly visible. Clamp a piece of clear wire gauze (seven mess per linear cm)125mm square in a horizontal position 6mm below the specimen with 6mm of the unsupported end of the specimen projecting beyond the edge of the gauze. Place a Bunsen centrally under the free end of the specimen so that the top of the burner is 50mm vertically below the longitudinal axis of the specimen. The temperature of the flame shall be such that a piece of 0.70mm diameter copper wire held 5cm above the of the burner melts within 6 seconds. Remove the flame after 30 seconds and record the time taken until the specimen ceases to flame or glow. In the event of the specimen extinguishing within 10 seconds of the removal of the flame, apply again the flame for a further 30 seconds.

(d) ASSESSMENT (VERY LOW FLAMMABILITY)

At least 3 or 4 specimens shall cease to flame or glow within 10 seconds of the removal of the flame and again and again within 10 seconds after the seconds removal of the flame.

(e) INSTRUENTS REQUIRED FOR TESTING (A) Draught free box (as per figure ‘B’)

(B) Bunsen Burner (C) Stop Watch (D) Die Mould for Resin Cast Sheet (E) Screw gauze ANNEXURE-2 IMPORTANT REQUIREMENTS OF THE MANUFACTURERS OF RESIN CAPSULES FOR USE IN MINES ************************************************************************ 1.0 For sake of ensuring the basic quality of the resin capsules being produced, the manufacturers shall process the following minimum equipments/facilities.

No Name of Equipment Quantity(Nos.)

Capacity Gel & Setting time Measuring Apparatus One --- Humidifier One Humidity 90% Temp.5 to 50.c Anchorage Testing Machine One 30 Tonnes Universal Testing Machine One 50 Tonnes Stop Watch Two ------ Flammability test set up One ---- Moulds Different Sizes ----- Glassware As Per req.

----- Draught free box A per drawing Bunsen burner Die mould for resin cast sheet.

Screw gauge Poking rod As per IS:10086:1982 Gauging trowel 100 to 150mm long & weight 210+1.c Refrigerator 4.c+1.C Punching tool assembly Punch dia of 12.575mm to 12.707mm to 12.723mm Film(LDPE)

One 5m long roll.

Compatible with resin matrix and catalyst.

Beam mould 25mm x 25mmx282mm internal length Length comparator As per IS:9459:1980 Flow table As per IS:5512:1969 Mercury Thermometer/ Thermo-couple Upto 150.c 2.0 In order to check the required parameters during manufacturing, it shall be required that the ramdom sampling be collected. Atleast one lot of sample containing adequate number/quantity of resin capsules for every 10,000 pieces of resin capsules manufactured, shall be subjected to all required set of tests as prescribed (standard) above and the data shall be kept recorded in a bound paged book kept for the purpose which shall be signed by the persons carrying out the test and countersigned by quality control office posted at the manufacturing unit(s). Such records shall be maintained for the purpose of verification for a period of atleast three years from the date of manufacturing.

3.0 The manufacturing firm shall prepare an elaborate usage and storage manual in respect of the batches of resin capsules manufactured for use in mines. With every consignment of resin capsules dispatched to a user, adequate number of usage and storage manuals shall also be furnished.

4.0 Resin Capsules having different Gel and Setting Times may be manufactured and supplied for different applications as required by the user, but the capsule should have valid approval and the gel & setting times shall be clearly superscripted on the capsule.

5.0 The manufacturing firm shall ensure that every consignment resin capsules dispatched is suitably protected against exposure to extreme to weather which could alter the properties of the resin capsules.

6.0 In case of any particular batch of rise capsules failing to meet the standards on “Short Encapsulation Pull Test (SEPT)”performed at the user end during joint testing, the manufacturer shall taken all steps to immediately intimate all other users to withdraw that particular batch which failed, from use and also confirm in writing to this Directorate within 24 hours of being intimated by the user.

********************** ANNEXURE-3 IMPORTANT REQUIREMENTS OF THE MINING COMPANIES USING RESIN CAPSULES ******************************************************************* 1.0 The mining companies using resin capsules for roof bolting purposes shall ensure the following.

a)

Proper arrangements are provided and maintained for storage of the resin capsules received in consultation with the respective manufacturers.

b) Adequate number of effective protective wears and gears are made available in every user mine for handling resin capsules.

2.0 Regular tests shall be carried out for assessment of get time and setting time in respect of the oldest batch stored in the mine, at a frequency not exceeding once a month.

3.0 Every mine shall carry out “short Encapsulation Pull Test (SEPT)” in a minimum of three horizons in the roof as may be determined by the Manager, in the presence of the representatives of the manufacturer.

Only those batch of capsules which satisfy the following minimum performance levels of SEPT as per the table given below shall be used underground for supporting purposes by roof bolts.

Short Encapsulation Pull Test after  30 Minutes.

 8 hours or 24 hours  10.0 Tonnes (for 20mm dia roof bolt).

12.0 Tonners (for 22 mm dia roof bolt)

 15.0 or 20.0 Tonnes respectively Net displacement measured during the SEPT(mm)

Not more the 15.

4.0 Such test shall be conducted for every batch of Resin Capsules received at mine and the results of the test shall be properly recorded in a bound paged book kept for the propose and also signed by the manager.

5.0 Where, the resin capsules received from a manufacture do not meet stipulated standards in respect of ”Short Encapsulation Pull Test (SEPT)” as above, a repeat of the same test shall be conducted in the presence of the representative of the manufacture and the results of the joint test report of the batch of resin capsules shall be properly recorded in a bound paged book kept for the purpose and also signed by the manager and the representative of the manufacturer.

6.0 If any Batch/consignment is proved failed in joint testing, it shall be ensured that the particular ‘failed’ batch of the resin capsules supplied shall be withdrawn from use in all mines of the company and intimation thereof shall be sent to this Directorate. A representative sample of the size as required for carrying out a complete laboratory test of the resin capsules of the batch/consignment which had failed during witnessing of tests by representatives of the mine and the manufacturer shall be immediately sent for testing in one or two approved test house(s). A copy of this report of test shall be furnished to this Directorate immediately on receipt from the test house.

7.0 Additionally, every mining company shall have an elaborate and properly functional Quality Insurances mechanism at Corporate/Area/Unit levels for ensuring use of quality resin capsules in mines and also for addressing problems of defective supply of resin Capsules. This mechanic shall provide for .

a)

Timely education of all manufacturer regarding dangers due to use of bad quality rein capsules,

b) Formulation of an elaborate code of practice for proper receipt, storage, regular testing for monitoring strength parameters during the storage period, handling and actual use in belowground working, including maintenance of signed records thereof in respect of each activity, c)

Ensuring submission of a batch test report by the manufacture with every batch of supply of resin capsules,

d) Regular joint sampling and testing along with manufacturer(s) at intervals as may at intervals as may be mutually agreed to, at NTH/DGMS approved laboratory for comprehensive testing of all stipulated parameters of the standard in force, e)

Submission of information regarding failed batches of supply of resin capsules to this Directorate thought the Nominated Owner along with a detailed enquiry report, and, f)

Taking such other steps as may be required in required in this regard in the interest of safety of persons involved.

*********************************************

Reproduced from the official DGMS circular compilations for public reference. The PDF is the authoritative text; DGMS may have amended or withdrawn older instructions since.

← Search all circulars