DGMS Circular (Tech.) Nc
Protocol on use, care, maintenance, sampling testing of Self Contained Seßf Rescuer (SCSQ) under Regcalatäon…
- Department
- Technical
- Year
- Not stated
- Collection
- Circulars 1995–2017
- Topic
- Circulars and notifications, 1995–June 2017
Part of this text was machine-read from a scanned page and may contain recognition errors. Check the original page before relying on it.
Directorate General of Mines Safety No, DGMS Circular (Tech.) Nc. Dß /Dhanbad, dated 28/6912015 The Owners, Agents, Managers of Coag Mines, Superintendent of Mines Rescue Stations, Manufacturers/Suppliers of Approved type of Self Contained Self Rescuers, Test Houses conducting tests of Self Contained Self Rescuers and all Officers of the Directorate Sub: Protocol on use, care, maintenance, sampling testing of Self Contained Seßf Rescuer (SCSQ) under Regcalatäon 191 D (2) 81 (3) of the Coal Mänes Regulations, 195% Jn view of the difficulties expressed by the users in use, care, sampling and maintenance of Self Contained Self Rescuers (SCSR) a meeting of users, regulators, scientific institutions, academicians and manufactures/suppliers was held on 19th May, 2015 to review issues related to use, care, maintenance, sampling & testing of Self Contained Self Rescuer (SCSR)
among other issues. This was followed by another meeting on 3rd June, 2015.
After detailed deliberations, the house opined that Condition No. 6 of Clause A and Condition No. 1.1 of Clause B of DGMS (Tech.) Circular No. 08 of 2008 dated 27.10.2008 requires modification and two new conditions may be incorporated.
2.
3.
USE, CARE MAINTENANCE Condition No. 6 of Clause A is modified as:
Every Self Contained Self Rescuer•(SCSR) on roll of the mine or mines rescue station shall be subjected to 'Leak Tightness Test', at least once in a quarter by a competent person duly authorized by the manager or superintendent of the mines rescue station for the purpose, in the manner as prescribed in the IS: 15803-2008 (Annexure E-1) under Clause 5.7 for Leak Tightness." Condition No. 1.1 of Clause B is modified as:
Before a batch of Self Contained Self Rescuer (SCSR) is put into service, samples at the rate of three percent (3%) subject to a minimum of twelve units, for even/ batch of supply shall be drawn at random for the testing by a joint sampling team comprising of representatives from manufacturer/supp!ier and user at the user's site." Batch testing of self rescuers may be performed at test houses prescribed in Clause (6.8 of the Approval Policy and in a mines rescue station, in presence of representatives of users and manufacturers who shall sign their respective attendance in a bound paged book kept for the purpose, before commencement and after completion of the tests.
4. Shelf life and service life of self rescuers shall be declared by the manufacturer, basecl on the prevailing practices and working, environment of the mines and would be subject ito fulfillment of prescribed conditions for their use. It shall be the responsibility of the user to certify the fitness of self rescuers for use in mines on quarterly basis or any other suitable interval as may be prescribed, which shall be recorded in a bound paged book kept for the purpose and duly countersigned by the mine manager/rescue superintendant/rescue room incharge.
5. All other provisions of the protocol issued Vide