DGMS (Tech) Circular No.2 of 2000 Dated the 31.1.2000 To The Owners, Agents and Managers of all coal mines.

Sub:

Use of Fire Resistant Hydraulic Fluid in Machinery used belowground in coal mines Use of approved type of fire resistant fluid in machinery working belowground coal mines is mandatory as required under Regulation 181(3) of Coal Mines Regulations, 1957.

Mineral oils are not suited for the purpose, as the same do not possess fire resistant properties.

I understand from the feedback from various coal companies that FRHF used in SDL and LHD machines have been found satisfactory in general but a few incidents/occurrences of jamming of valves, premature failure of seals, breaking up of the emulsion, premature failure of pump have been reported.

In view of safe and effective use of the fluid, following guidelines shall be strictly complied with.

1. Contamination in the fluid:

Contamination of hydraulic system can cause tremendous damage t the hydraulic system. In mineral oils, the contaminations present may settle down at the bottom of the tank but in emulsified FRHF, the contamination like coal dust etc. may not settle down and the whole contamination/particles travel at high speed which may cause enormous damage to seals/gaskets, pumps etc.

The problem can be solved by two ways:

(i)

Change of filters at an interval of 500 hours as recommended by the equipment manufacturer.

(ii)

Maximum contamination takes place during topping up of the fluid by opening of the lid of the tank in the coal face. Such manual topping up shall be discouraged.

Topping up must be carried out directly from the fluid container to the tank by hose pipe with the assistance of hand pumps provided by the equipment manufacturer. Maximum contamination level has been indicated by M/s.IOC in one of the seminars shall be 0.1% of the fluid by weight provided the contamination is abrasive like coal/silica. But it requires further study by the users, oil manufacturers and equipment manufacturers.

2.

Life of FRHF:

Since contamination play a vital role in the safe use of the fluid, apart from complying the recommendation mentioned at para 1, the hydraulic system including the tank of each machine shall be cleaned atleast once in a year and charged with fresh fluid after replacing the filter by a new one.

3.

Mixing of FRHF of different make:

Basic petroleum oils in the fluid may be of different makes and additives added may also be different, so it is not recommended at present to mix the fluids during use. A detailed study on the effect of mixing of fluids of different makes on stability, wear and corrosion I needed before inter mixing of various fluids.

4.

Seal/gasket compatibility:

The various fluids may affect the various seals in different proportion depending up the polymeric material used. Equipment manufacturer should indicate the compatibility of recommended fluid with the seals used by them.

5.

Quick analyzer to assess the percentage of water in oil It is necessary to maintain water level between 36% to 42% in the HFB fluid and to ascertain the water content, samples must be drawn atleast once in three month. Availability of refractometers for quick analyzing of oil/water percentage for HFA fluid for powered roof supports is not a problem. But in fluids where the oil content is nearly 60% as in HFB, such refractometers do not work. Each oil manufacturer shall provide a method of breaking of the sample of fluid and method to determine water content at site.

It is, therefore, essential that the users shall initiate all actions as per the guidelines mentioned above and they shall procure only those equipments which are compatible with the particular FRHF as recommended by the equipment manufacturer.