DGMS(Tech.) (S&T)/Circular No.3/703 Dhanbad, dated the 14.08.2008 To The Owner, Agent & Manager of Coal Mines Subject: Approval of Steel Supports, Roof Bolts, Cement and Resin Grouts to be used in Mines.
Sir, In any underground excavations, the stability of roof and sides, not only depends on the nature of rocks but also on the system of supports used therein. Most of the underground accidents especially in coal mines occur due to fall of roof and sides. Almost thirty five to forty percent of the underground fatal accidents occur due to fall of roof and sides. Now a day, timber supports are being replaced by steel supports in the form of props and cogs/chocks in addition to roof bolts with cement or resin grouts.
As per the statutory provisions made in the Coal Mines Regulations, 1957 as well as the Metalliferous Mines Regulation, 1961, the systematic support rules are to be framed by the manager of the mines and the requirement as well as the system of support is to be planned and specified in the SSRs. A number of technical circulars regarding type of supports, code of practices for setting of support, testing, examination and withdrawal of supports have been issued from this Directorate from time to time. However, the fatal accidents due to fall of roof and sides are still recurring of and on in most of the underground coal mines in the country.
During the course of inspections as well as enquiries into the accidents due to fall of roof and sides, it has been observed that :- Either the required support is not being provided at the working places or the quality of support including support materials such as type of steels used in props/chocks/cogs were not of required strengths and dimensions.
The welding done to join the cogging members of the cock/cog was not of required standard resulting in failure of cogs/chock at lower loads during use.
The quality of steel used in the roof bolts was not of required strengths and dimensions. The threading done on the roof bolt was also not treated properly resulting weakness in the rock bolt causing failure from threads during loads.
Cement Grout is being used in watery strata without assessing the water quality and compatibility with cement grouts in respect of its strength variation with respect to time. In number of cases, the roof falls had occurred along with roof bolts and after testing of the installed bolts in the area it was observed that the bolts were failing at loads varying from 2 to 6 Tonnes.
The quality of cement grouts used for grouting of the roof bolts was also not checked for required strength and thereby the roof bolts have reportedly failed at less than the required load. In most of the cases, the failure occurred either in the cement steel contact or cement rock contact or at thread of the rock bolt. It has also further been observed that proper pull tests were not being carried out in the mine to ascertain the quality of roof bolts and the grouts before putting in use in the mine. A number of fatal accidents have occurred due to failure of the roof bolts in the working places.
In some cases, itching and irritations have also been reported due to cement grout solution falling on to the body or into the eyes of the roof bolts grouting crews.
It is also observed during the course of inspection and enquiry at the mines that no quality checks and procedures are being followed to ensure good quality roof bolts, cement and resin grouts as well as steel cogs and props.
Resin is also now being used for grouting the roof bolts which provides fast support at the working places especially in the green roof areas. Various types of resins including slow and fast setting types are being used in roof bolting. Since this is a quick setting type of supports suitable for green roof area, it is desired that the quality of the roof bolts and the resins should be ensured to have an effectives support in active working areas/places. Short encapsulation pull test is to be conducted to ascertain the load bearing capacity of the support before use of every lot of resin capsules. During the course of inspection and testing of resin bolts, it has been found that- I.
The roof bolts has failed from their threads.
II.
The roof bolts were pulled at very low load due to non setting of the resin.
III.
The resin grouts had weathered and crumbled into powder form after elapse of 2 to 3 months thereby making the roof bolts ineffective.
IV.
The Shelf Life of the resin capsule was less than the specified period.
V.
Expired resin capsules were being used in roof bolting resulting in improper grouting thereby reducing the strength of the roof bolts.
This reveals that a good quality control measures is required to ensure the quality of resin as well as its strength characteristic profile with respect to time.
In order to standardize the system of supports, it is essential to have uniform scale and standard for type of steels to be used for steel props, chocks and cogs including roof bolts. The similar standards would also be required to ensure the quality of cement as well as resin to be used as grouting materials for the support system. Non-toxic and biodegradable chemicals can only be used grouting materials.
It is therefore, decided to include all types of steel supports, roof bolts, cement and resin grouts under item to be approved from this Directorate before use in mines.
A Notification No. DGMS/S&T/SS/702 dated 14th August 2008 in this regard has been forwarded to be published in the Gazette of India and the subject matter thereof is reproduced below for information and taking necessary actions to comply with the requirement.
“In exercise of the power conferred on the Chief Inspector of Mines also designated as Director General of Mines Safety under sub-regulation (3) of Regulation 181 of the Coal Mines Regulations, 1957, I hereby declare 1st November, 2008 as the date from which all types of steel supports, roof bolts, cement and resin grouts to be used for the purpose of supporting roof and sides of workings in a mine, shall be of such type, standard and make as approved by me by a general or special order in writing.” You are being informed in advance to take necessary steps in this regard and requested to ensure that it is implemented and complied with.